| App Key |
MRC | Mode Code |
Requirements |
|---|---|---|---|
|
|
|||
| ALL | |||
| NAME | D | ITEM NAME | |
| Definition: A NOUN, WITH OR WITHOUT MODIFIERS, BY WHICH AN ITEM OF SUPPLY IS KNOWN. | |||
| Reply Instructions: Enter the applicable Item Name Code from the index appearing in the General Information Section. (e.g., NAMED00511*) | |||
|
|
|||
| ALL | |||
| BHSX | D | CIRCUIT CONSTRUCTION TYPE | |
| Definition: INDICATES THE TYPE OF CIRCUIT CONSTRUCTION PROVIDED IN THE ITEM. | |||
| Reply Instructions: Enter the applicable REPLY CODEfrom the table below. (e.g., BHSXDAF*; BHSXDAW$$DAF*) | |||
| REPLY CODE | REPLY (AM43) |
|---|---|
| A | ANY ACCEPTABLE |
| AW | ELECTRON TUBE |
| AF | SOLID STATE |
| A*, B*, C*, D*, E*, F*, G*, H*, J*, K*, L*, M*, N*, Q* | |||
| BHTB | J | FREQUENCY PER CHANNEL | |
| Definition: THE PORTION OF THE FREQUENCY SPECTRUM AT WHICH AN ITEM IS DESIGNED TO RECEIVE OR TRANSMIT SIGNAL POWER. | |||
| Reply Instructions: Enter the applicable Reply Codes from Tables 1 and 2 below and Appendix A, Table 1 , followed by the numeric value. (e.g., BHTBJKAAAM940.0*; BHTBJKBAAM935.0$$JKCAAM945.0*) | |||
| If there is a specified range of frequencies or more than one channel, use Secondary Address Coding, entering replies in Appendix A, Table 1 sequence. (e.g., | |||
| BHTB1AJKBAAG900.0$$JKCAAG940.0* | |||
| BHTB1BJKAAAM940.0*) | |||
| For items that do not require a rating, change the Mode Code to K and enter REPLY CODE N. (e.g., BHTBKN*) | |||
| Table 1 | |
|---|---|
| REPLY CODE | REPLY (AC32) |
| G | GIGAHERTZ |
| E | HERTZ |
| K | KILOHERTZ |
| M | MEGAHERTZ |
| Table 2 | |
|---|---|
| REPLY CODE | REPLY (AC20) |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
| A*, B*, C*, D*, E*, F*, G*, H*, J*, K*, L*, M*, N*, Q* | |||
| BHSY | A | SWITCHING RATE PER SECOND | |
| Definition: THE NUMBER OF SWITCHING CYCLES THAT OCCUR PER SECOND. | |||
| Reply Instructions: Enter the quantity. (e.g., BHSYA1500*) | |||
| If more than one channel is included in the item, use Secondary Address Coding, entering a reply for each in the same sequence established for MRC BHTB. (e.g., | |||
| BHSY1AA1925* | |||
| BHSY1BA2560*) | |||
|
|
|||
| A*, B*, C*, D*, E*, F*, G*, H*, J*, K*, L*, M*, N*, Q* | |||
| BHSZ | J | FREQUENCY SHIFT | |
| Definition: THE SHIFT OF THE FREQUENCY OF THE ITEM. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the numeric value. (e.g., BHSZJK20.0*; BHSZJK1.0$$JK2.0*; BHSZJE200.0$$JK1.0*) | |||
| REPLY CODE | REPLY (AC32) |
|---|---|
| G | GIGAHERTZ |
| E | HERTZ |
| K | KILOHERTZ |
| M | MEGAHERTZ |
| A*, B*, C*, D*, E*, F*, G*, H*, J*, K*, L*, M*, N*, Q* | |||
| BHTD | D | FREQUENCY ADJUSTMENT TYPE | |
| Definition: INDICATES THE TYPE OF FREQUENCY ADJUSTMENT INCLUDED IN THE ITEM. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., BHTDDE*) | |||
| REPLY CODE | REPLY (AD63) |
|---|---|
| E | CONTINUOUS |
| J | STEPPED |
| NOTE FOR MRC BHTF: REPLY TO THIS MRC ONLY IF REPLY CODE J IS ENTERED FOR MRC BHTD. | |||
| A*, B*, C*, D*, E*, F*, G*, H*, J*, K*, L*, M*, N*, Q* ( See Note Above) | |||
| BHTF | J | INDIVIDUAL STEP FREQUENCY | |
| Definition: THE FREQUENCY OF EACH STEP. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the numeric value. (e.g., BHTFJK20.0*; BHTFJK2.7$$JK2.9*) | |||
| REPLY CODE | REPLY (AC32) |
|---|---|
| G | GIGAHERTZ |
| E | HERTZ |
| K | KILOHERTZ |
| M | MEGAHERTZ |
| A*, B*, C*, D*, E*, F*, G*, H*, J*, K*, L*, M*, N*, Q* | |||
| BHTG | B | VARIATION FREQUENCY RATING IN DECIBELS | |
| Definition: THE AMOUNT OF ALLOWABLE VARIATION RELATIVE TO A SPECIFIED FREQUENCY LEVEL, EXPRESSED IN DECIBELS. | |||
| Reply Instructions: Enter the numeric value. (e.g., BHTGB3.5*; BHTGBM1.5$$B1.5*) | |||
|
|
|||
| A*, B*, C*, D*, E*, F*, G*, H*, J*, K*, L*, M*, N*, Q* | |||
| AJVF | J | PHASE SHIFT ANGLE IN DEG | |
| Definition: THE DIFFERENCE BETWEEN THE PHASE TIME OF TWO OR MORE VOLTAGES OR CURRENTS OF THE SAME FREQUENCY, AT THE SAME INSTANT OF TIME, EXPRESSED IN DEGREES. | |||
| Reply Instructions: Enter the applicable Reply Codes from Tables 1 and 2 below, followed by the numeric value. (e.g., AJVFJABA4.5*; AJVFJABB4.0$$JABC5.0*) | |||
| If the source document does not specify the element comparison used, enter REPLY CODE AB from Table 1. | |||
| Table 1 | |
|---|---|
| REPLY CODE | REPLY (AG04) |
| AB | INPUT TO OUTPUT |
| AC | OUTPUT TO INPUT |
| Table 2 | |
|---|---|
| REPLY CODE | REPLY (AC20) |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
| NOTE FOR MRC AFBH: REPLY TO THIS MRC ONLY IF MORE THAN ONE FREQUENCY HAS BEEN ENTERED FOR MRC BHTB. | |||
| A*, B*, C*, D*, E*, F*, G*, H*, J*, K*, L*, M*, N*, P*, Q* (See Note Above) | |||
| AFBH | A | INDIVIDUAL SECTION QUANTITY | |
| Definition: THE NUMBER OF INDIVIDUAL SECTIONS INCLUDED IN THE ITEM. | |||
| Reply Instructions: Enter the quantity. (e.g., AFBHA2*) | |||
| ALL * | |||
| BHTH | B | ATTENUATION IN DECIBELS | |
| Definition: THE DECREASE IN STRENGTH OF AN ELECTRICAL IMPULSE, EXPRESSED IN DECIBELS. | |||
| Reply Instructions: Enter the numeric value. (e.g., BHTHB2.0*) | |||
| If an attenuation range is reflected in the source data, use Secondary Address Coding, entering the lowest value first. (e.g., | |||
| BHTH1AB3.0* | |||
| BHTH1BB10.0*) | |||
| For items that do not require a rating, change the Mode Code to K and enter REPLY CODE N. (e.g., BHTHKN*) | |||
|
|
|||
| ALL * | |||
| BHTJ | J | AVERAGE PER CHANNEL POWER RATING | |
| Definition: THE RATED AVERAGE POWER FOR EACH CHANNEL. | |||
| Reply Instructions: Enter the applicable Reply Codes from Tables 1 and 2 below, followed by the numeric value. (e.g., BHTJJWF100.0*) | |||
| If the item is rated for both input and output, use Secondary Address Coding, entering both ratings in Table 2 reply sequence. (e.g., | |||
| BHTJ1AJWB100.0* | |||
| BHTJ1BJWF150.0*) | |||
| For items that do not require a rating, change the Mode Code to K and enter REPLY CODE N. (e.g., BHTJKN*) | |||
| Table 1 | |
|---|---|
| REPLY CODE | REPLY (AC33) |
| L | KILOWATTS |
| R | MEGAWATTS |
| M | MILLIWATTS |
| W | WATTS |
| Table 2 | |
|---|---|
| REPLY CODE | REPLY (AC00) |
| B | INPUT |
| F | OUTPUT |
| ALL * | |||
| BHTK | J | SIGNAL VOLTAGE RATING PER CHANNEL | |
| Definition: THE RATED SIGNAL VOLTAGE FOR EACH CHANNEL. | |||
| Reply Instructions: Enter the applicable Reply Codes from Tables 1, 2, and 3 below, followed by the numeric value. (e.g., BHTKJVAF25.000*; BHTKJVBF20.000$$JVCF30.000*) | |||
| If the item is rated for input and output, use Secondary Address Coding, entering replies in Table 3 sequence. (e.g., | |||
| BHTK1AJVBB10.500$$JVCB25.000* | |||
| BHTK1BJVBF60.500$$JVCF75.000*) | |||
| For items that do not require a rating, change the Mode Code to K and enter REPLY CODE N. (e.g., BHTKKN*) | |||
| Table 1 | |
|---|---|
| REPLY CODE | REPLY (AB63) |
| K | KILOVOLTS |
| M | MEGAVOLTS |
| U | MICROVOLTS |
| L | MILLIVOLTS |
| V | VOLTS |
| Table 2 | |
|---|---|
| REPLY CODE | REPLY (AC20) |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
| Table 3 | |
|---|---|
| REPLY CODE | REPLY (AC00) |
| B | INPUT |
| F | OUTPUT |
| ALL * | |||
| BHTL | J | OVERALL GAIN | |
| Definition: THE INCREASE IN ENERGY FROM THE INPUT TO THE OUTPUT. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the numeric value. (e.g., BHTLJAD3.0*) | |||
| If rated for more than one value, use Secondary Address Coding entering replies in ascending sequence. (e.g., | |||
| BHTL1AJAD3.0* | |||
| BHTL1BJAD5.0*) | |||
| For items that do not require a rating, change the Mode Code to K and enter REPLY CODE N. (e.g., BHTLKN*) | |||
| REPLY CODE | REPLY (AB49) |
|---|---|
| AA | AMPERES |
| AD | DECIBELS |
| BA | MILLIAMPERES |
| BB | MILLIVOLTS |
| AS | VOLTS |
| ALL * | |||
| BHTN | J | IMPEDANCE RATING PER CHANNEL | |
| Definition: THE TOTAL OPPOSITION (RESISTIVE AND REACTIVE) TO THE FLOW OF ALTERNATING CURRENT PER CHANNEL. | |||
| Reply Instructions: Enter the applicable Reply Codes from the table below and Appendix A, Table 1 , followed by the numeric value. (e.g., BHTNJQRAAB25.750*) | |||
| If the item is rated for both input and output, use Secondary Address Coding, entering both ratings in Appendix A, Table 1 reply sequence. (e.g., | |||
| BHTN1AJKRAAG1.125* | |||
| BHTN1BJKRAAM2.000*) | |||
| For items that do not require a rating, change the Mode Code to K and enter REPLY CODE N. (e.g., BHTNKN*) | |||
| REPLY CODE | REPLY (AE75) |
|---|---|
| GF | GIGOHMS |
| KR | KILOHMS |
| MR | MEGOHMS |
| MC | MICROHMS |
| ML | MILOHMS |
| QR | OHMS |
| ALL * | |||
| ALBM | D | OPERATING CONTROL METHOD | |
| Definition: THE MEANS BY WHICH THE ITEM IS OPERATED OR CONTROLLED. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., ALBMDAB*; ALBMDAB$DAF*) | |||
| REPLY CODE | REPLY (AH20) |
|---|---|
| AB | AUTOMATIC |
| AF | MANUAL |
| ALL * | |||
| AQZF | D | CONTROL TYPE | |
| Definition: INDICATES THE TYPE OF CONTROL. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., AQZFDACK*; AQZFDACK$DAAY*) | |||
| REPLY CODE | REPLY (AL37) |
|---|---|
| ACK | LOCAL |
| AAY | REMOTE |
| ALL * | |||
| BJBL | J | INDICATOR DEVICE TYPE AND QUANTITY | |
| Definition: INDICATES THE TYPE AND NUMBER OF INDICATOR DEVICE(S) INCLUDED. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the quantity. (e.g., BJBLJADS1*) | |||
| If more than one type is included, use AND coding ($$), entering replies in reply table sequence. (e.g., BJBLJADS1$$JACJ2*) | |||
| REPLY CODE | REPLY (AJ12) |
|---|---|
| AKB | AUDIBLE ALARM |
| ADS | CATHODE RAY TUBE |
| AKK | HEADSET |
| ACE | LIGHT (lamp) |
| AKD | LOUDSPEAKER |
| ACJ | METER |
| ALL * | |||
| BJBM | B | MAXIMUM CONTINUOUS OPERATING TIME IN HOURS | |
| Definition: THE MAXIMUM TIME AN ITEM WILL CONTINUOUSLY RUN, EXPRESSED IN HOURS. | |||
| Reply Instructions: Enter the numeric value. (e.g., BJBMB6.7*) | |||
| For items that do not require a rating, change the Mode Code to K and enter REPLY CODE N. (e.g., BJBMKN*) | |||
|
|
|||
| ALL | |||
| AFSU | D | AVERAGE LIFE MEASUREMENT | |
| Definition: A TERM USED TO DENOTE THE SPECIFIC MEASUREMENT OF DURATION USED TO INDICATE THE AVERAGE LIFE OF THE ITEM. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., AFSUDB*) | |||
| REPLY CODE | REPLY (AE52) |
|---|---|
| N | NOT RATED |
| B | HOURS |
| C | INDEFINITE |
| A | YEARS |
| NOTE FOR MRC AFHH: REPLY TO THIS MRC ONLY IF REPLY CODE B OR A IS ENTERED FOR MRC AFSU. | |||
| ALL * (See Note Above) | |||
| AFHH | B | AVERAGE LIFE RATING | |
| Definition: THE NUMERIC VALUE OF THE LIFE EXPECTANCY OF THE ITEM. | |||
| Reply Instructions: Enter the numeric value. (e.g., AFHHB15.0*) | |||
|
|
|||
| ALL * | |||
| AKAE | J | MAXIMUM OPERATING ALTITUDE RATING | |
| Definition: THE MAXIMUM ALTITUDE AT WHICH THE ITEM IS RATED TO FUNCTION. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the numeric value. (e.g., AKAEJF15000.0*; AKAEJM4500.0*) | |||
| For items that do not require a rating, change the Mode Code to K and enter REPLY CODE N. (e.g., AKAEKN*) | |||
| REPLY CODE | REPLY (AA05) |
|---|---|
| F | FEET |
| M | METERS |
| ALL * | |||
| AFGA | J | OPERATING TEMP RANGE | |
| Definition: THE MINIMUM AND MAXIMUM LIMITS OF TEMPERATURE AT WHICH THE ITEM IS RATED FOR OPERATION. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the numeric values separated by a slash. Precede negative values with an M and positive values with a P. (e.g., AFGAJFM40.0/P100.0*) | |||
| For items that do not require a rating, change the Mode Code to K and enter REPLY CODE N. (e.g., AFGAKN*) | |||
| REPLY CODE | REPLY (AB36) |
|---|---|
| C | DEG CELSIUS |
| F | DEG FAHRENHEIT |
| ALL * | |||
| AECR | F | VIBRATION RESISTANCE RANGE IN HERTZ | |
| Definition: THE LOW AND HIGH FREQUENCIES OF VIBRATORY MOTION AND MECHANICAL STRESSES BETWEEN WHICH THE ITEM IS TESTED, OR OPERATED, WITHOUT DELETERIOUS EFFECT ON ITS ELECTRICAL OR MECHANICAL CHARACTERISTICS, EXPRESSED IN HERTZ. | |||
| Reply Instructions: Enter the numeric values separated by a slash. Precede all values with a P. (e.g., AECRFP10.0/P5000.0*) | |||
| For multiple ranges, use AND coding ($$), entering replies in ascending numeric sequence. (e.g., AECRFP5.0/P15.0$$FP16.0/P25.0$$FP26.0/P33.0*) | |||
| For items that do not require a rating, change the Mode Code to K and enter REPLY CODE N. (e.g., AECRKN*) | |||
|
|
|||
| ALL * | |||
| AFDN | J | VIBRATION RESISTANCE AMPLITUDE | |
| Definition: THE AMPLITUDE OF VIBRATION FOR WHICH THE VIBRATION RESISTANCE FREQUENCY RANGE APPLIES. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the numeric value. (e.g., AFDNJB10.0*) | |||
| For multiple ranges, use AND coding ($$), entering replies in the same sequence established for MRC AECR. (e.g., AFDNJB3.5$$JB6.5$$JB5.5*) | |||
| REPLY CODE | REPLY (AD97) |
|---|---|
| D | CENTIMETERS TOTAL EXCURSION |
| B | GRAVITATIONAL UNITS |
| C | INCHES TOTAL EXCURSION |
| ALL * | |||
| AFDP | B | SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS | |
| Definition: THE MAXIMUM FORCE AT IMPACT THAT THE ITEM IS RATED TO WITHSTAND, WITHOUT RESULTING IN ANY PERMANENT CHANGE IN PHYSICAL OR ELECTRICAL CHARACTERISTICS, EXPRESSED IN GRAVITATIONAL UNITS (G's). | |||
| Reply Instructions: Enter the numeric value. (e.g., AFDPB50.0*) | |||
| For items that do not require a rating, change the Mode Code to K and enter REPLY CODE N. (e.g., AFDPKN*) | |||
|
|
|||
| ALL * | |||
| BJBN | J | SHOCK PULSE DURATION TIME | |
| Definition: THE LENGTH OF TIME AFTER IMPACT THAT ESTABLISHED THE CONDITION AT WHICH THE SHOCK RESISTANCE RATING APPLIES. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the numeric value. (e.g., BJBNJBK25.0*) | |||
| REPLY CODE | REPLY (AB49) |
|---|---|
| AL | MICROSECONDS |
| BK | MILLISECONDS |
| ALL * | |||
| BKFB | J | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | |
| Definition: THE VALUE(S) OF THE POTENTIAL SUPPLIED FROM AN EXTERIOR DIRECT CURRENT SOURCE TO OPERATE THE ITEM, EXPRESSED IN VOLTS. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below and from Appendix A, Table 5 , followed by the numeric value. (e.g., BKFBJAAA12.0*; BKFBJBAA11.5$$JCAA12.5*) | |||
| For multiple replies, use Secondary Address Coding, entering replies in Appendix A, Table 5 sequence. (e.g., | |||
| BKFB1AJAAC190.0* | |||
| BKFB1BJBAD200.0$$JCAD250.0* | |||
| BKFB1CJAAE500.0*) | |||
| REPLY CODE | REPLY (AC20) |
|---|---|
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
| ALL * | |||
| BKFC | J | EXTERNAL AC OPERATING VOLTAGE IN VOLTS | |
| Definition: THE VALUE(S) OF THE POTENTIAL SUPPLIED FROM AN EXTERIOR ALTERNATING CURRENT SOURCE TO OPERATE THE ITEM, EXPRESSED IN VOLTS. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below and from Appendix A, Table 5 , followed by the numeric value. (e.g., BKFCJAAA110.0*; BKFCJBAA100.0$$JCAA110.0*) | |||
| For multiple replies, use Secondary Address Coding, entering replies in Appendix A, Table 5 sequence. (e.g., | |||
| BKFC1AJAAC125.0* | |||
| BKFC1BJBAD130.0$$JCAD150.0* | |||
| BKFC1CJAAE300.0*) | |||
| REPLY CODE | REPLY (AC20) |
|---|---|
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
| ALL * | |||
| BJBQ | J | OPERATING AC FREQUENCY IN HERTZ | |
| Definition: THE CYCLES PER SECOND (HERTZ) OF THE OPERATING ALTERNATING CURRENT. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below and from Appendix A, Table 5 , followed by the numeric value. (e.g., BJBQJAAA60.0*; BJBQJBAA50.0$$JCAA60.0*) | |||
| If multiple AC voltages are given in the source data, use AND coding ($$), giving the frequency of each, entering replies in the same sequence as replies to MRC BKFC. (e.g., | |||
| BJBQ1AJAAC47.0* | |||
| BJBQ1BJAAD395.0$$JAAD405.0*) | |||
| REPLY CODE | REPLY (AC20) |
|---|---|
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
| ALL * | |||
| FAAZ | D | PHASE | |
| Definition: THE NUMBER OF ALTERNATING CURRENT PHASES. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., FAAZDA*) | |||
| If multiple AC voltages are given in the source data, use Secondary Address Coding, entering the phase of each. (e.g., | |||
| FAAZ1ADA* | |||
| FAAZ1BDC*) | |||
| REPLY CODE | REPLY (AD02) |
|---|---|
| A | SINGLE |
| E | SINGLE/THREE |
| C | THREE |
| B | TWO |
| ALL * | |||
| BJBP | H | CONNECTION TYPE AND LOCATION | |
| Definition: INDICATES THE TYPE OF CONNECTION AND ITS LOCATION ON THE ITEM. | |||
| Reply Instructions: Enter the applicable REPLY CODE from Appendix A, Table 4 , followed by the applicable REPLY CODEfrom the table below. (e.g., BJBPHFDABC*) | |||
| For multiple replies, use AND coding ($$), entering replies in location sequence. (e.g., BJBPHFHABC$$HFAABJ$$HFJABJ*) | |||
| REPLY CODE | REPLY (AJ91) |
|---|---|
| ABA | BOTTOM |
| ABC | FRONT |
| ACF | LEFT SIDE |
| ABJ | REAR |
| ACR | RIGHT SIDE |
| ABD | TOP |
| NOTE FOR MRC BJBW: REPLY TO THIS MRC IF OTHER THAN REPLY CODE FE OR FF WAS SELECTED FROM Appendix A, Table 4 , IN REPLY TO MRC BJBP. | |||
| ALL * (See Note Above) | |||
| BJBW | J | CONNECTION CONTACT TYPE AND QUANTITY | |
| Definition: INDICATES THE TYPE AND NUMBER OF CONTACT(S) INCLUDED IN THE CONNECTION. | |||
| Reply Instructions: Enter the applicable REPLY CODE from Appendix A, Table 4 , and from the table below, followed by the quantity. (e.g., BJBWJFCCT4*) | |||
| If multiple connections are included on the item, use AND coding ($$), entering a reply for each connection in Appendix A, Table 4 REPLY CODE sequence. (e.g., BJBWJFDCT12$$JFHCW23$$JFKCT14*) | |||
| REPLY CODE | REPLY (AG81) |
|---|---|
| CW | EXTERNAL |
| CT | INTERNAL |
| NOTE FOR MRC BJBT: REPLY TO THIS MRC ONLY WHEN REPLY CODE FM OR FN WAS SELECTED FROM Appendix A, Table 4 , FOR MRC BJBP. | |||
| ALL * (See Note Above) | |||
| BJBT | J | MAXIMUM CONNECTION PRESSURE RATING | |
| Definition: THE MAXIMUM RATED PRESSURE THAT A CONNECTION CAN WITHSTAND WITHOUT RUPTURE. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below and from Appendix A, Table 4 , followed by the numeric value. (e.g., BJBTJVFC300.0*; BJBTJKFC141.3*) | |||
| If multiple connections are included on the item, use AND coding ($$), entering a reply for each connection in the same sequence as established for MRC BJBP. (e.g., BJBTJVFC500.0$$JVFD300.0*) | |||
| REPLY CODE | REPLY (AB18) |
|---|---|
| K | KILOGRAMS PER SQUARE CENTIMETER |
| V | POUNDS PER SQUARE INCH |
| ALL | |||
| AKNA | D | INCLOSURE TYPE | |
| Definition: INDICATES THE TYPE OF INCLOSURE PROVIDED TO COAT, COVER, PROTECT, OR ENCASE THE ITEM. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., AKNADAC*) | |||
| REPLY CODE | REPLY (AG85) |
|---|---|
| AC | ENCAPSULATED |
| AN | ENCASED |
| AD | HERMETICALLY SEALED |
| AE | OPEN |
| AP | PARTIALLY INCLOSED |
| ALL * | |||
| ADZC | D | ENVIRONMENTAL PROTECTION | |
| Definition: THE ENVIRONMENTAL ELEMENTS OR CONDITIONS THAT AN ITEM IS DESIGNED OR PROTECTED TO RESIST OR WITHSTAND SATISFACTORILY. | |||
| Reply Instructions: Enter the applicable REPLY CODE from Appendix A, Table 6 . (e.g., ADZCDBV*) | |||
| For items designed to operate in more than one environment, use AND coding ($$), entering replies in Appendix A, Table 6 REPLY CODE sequence. (e.g., ADZCDCM$$DGN*) | |||
|
|
|||
| NOTE FOR MRC AKAP: REPLY TO THIS MRC ONLY IF REPLY CODE CB OR CH IS ENTERED FOR MRC ADZC. | |||
| ALL * (See Note Above) | |||
| AKAP | J | PROOF PRESSURE | |
| Definition: THE MAXIMUM PRESSURE THAT AN ITEM WILL WITHSTAND WITHOUT RESULTING IN ANY PERMANENT CHANGES IN ITS STRUCTURAL, MECHANICAL, OR ELECTRICAL CHARACTERISTICS. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the numeric value. (e.g., AKAPJV500.0*; AKAPJK230.5*) | |||
| REPLY CODE | REPLY (AB18) |
|---|---|
| K | KILOGRAMS PER SQUARE CENTIMETER |
| V | POUNDS PER SQUARE INCH |
| ALL | |||
| AMQY | D | INSTALLATION DESIGN | |
| Definition: THE INSTALLATION FOR WHICH THE ITEM IS DESIGNED. | |||
| Reply Instructions: Enter the applicable REPLY CODE from Appendix A, Table 7 . (e.g., AMQYDCB*; AMQYDCD$$DAZ*) | |||
|
|
|||
| ALL | |||
| AGTA | L | BASIC SHAPE STYLE | |
| Definition: THE STYLE DESIGNATION INDICATING THE CONFIGURATION THAT MOST NEARLY CORRESPONDS TO THE BASIC APPEARANCE OF THE ITEM. | |||
| Reply Instructions: Enter the applicable REPLY CODE from Appendix B, Reference Drawing Group A . (e.g., AGTAL1*) | |||
|
|
|||
| ALL * | |||
| AJKH | G | IDENTIFICATION DESIGNATOR | |
| Definition: A DESIGNATION ASSIGNED TO THE ITEM FOR PURPOSE OF READY IDENTIFICATION. | |||
| Reply Instructions: Enter the document designator, a dash, and the 5-position Commercial and Government Entity (CAGE) Code. | |||
| (e.g., AJKHGAM2016FPR2-80058*) | |||
|
|
|||
| NOTE FOR MRCS CBBL AND FEAT: E MODE REPLIES WILL NOT BE ACCEPTED IN REPLY TO MRC CBBL. IF A REPLY IS NOT REFERENCED ON THE TABLE, ENTER THE FEATURE IN REPLY TO MRC FEAT. | |||
| ALL * (See Note Above) | |||
| CBBL | D | FEATURES PROVIDED | |
| Definition: THOSE FEATURES, NOT OTHERWISE SPECIFIED, WHICH MAY BE REQUIRED FOR PROPER FUNCTIONING OF THE ITEM. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., CBBLDAABS*) | |||
| For multiple replies, use AND coding ($$), entering in REPLY CODE sequence. (e.g., CBBLDAABS$$DAABT*) | |||
| REPLY CODE | REPLY (AN47) |
|---|---|
| AADS | AUTOMATIC GAIN CONTROL |
| AABT | INTERNAL BATTERY ACCOMMODATION |
| AABS | ZERO SHIFT CAPABILITY |
| NOTE FOR MRC RADC: REPLY TO THIS MRC ONLY WHEN THE ITEM CONTAINS RADIOACTIVE MATERIAL. | |||
| IF MRC RADC IS ANSWERED, A REPLY TO MRC RADD IN SECTION III IS MANDATORY. | |||
| ALL * (See Note Above) | |||
| RADC | D | RADIOACTIVE CONTENT | |
| Definition: AN INDICATION OF WHETHER OR NOT THE ITEM CONTAINS RADIOACTIVE MATERIALS. | |||
| Reply Instructions: Enter the REPLY CODE from the table below. (e.g., RADCDP*) | |||
| REPLY CODE | REPLY (AN54) |
|---|---|
| P | CONTAINS RADIOACTIVE MATERIAL |
| ALL * (See Note Preceding MRC CBBL) | |||
| FEAT | G | SPECIAL FEATURES | |
| Definition: THOSE UNUSUAL OR UNIQUE CHARACTERISTICS OR QUALITIES OF AN ITEM NOT COVERED IN THE OTHER REQUIREMENTS AND WHICH ARE DETERMINED TO BE ESSENTIAL FOR IDENTIFICATION. | |||
| Reply Instructions: Enter the reply in clear text. Separate multiple replies with a semicolon. (e.g., FEATGADJUSTABLE NOSE CLIP*; FEATGADJUSTABLE NOSE PIECE; DISPOSABLE*) | |||
|
|
|||
| ALL* | |||
| TEST | J | TEST DATA DOCUMENT | |
| Definition: THE SPECIFICATION, STANDARD, DRAWING, OR SIMILAR INSTRUMENT THAT SPECIFIES ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS OR TEST CONDITIONS UNDER WHICH AN ITEM IS TESTED AND ESTABLISHES ACCEPTABLE LIMITS WITHIN WHICH THE ITEM MUST CONFORM IDENTIFIED BY AN ALPHABETIC AND/OR NUMERIC REFERENCE NUMBER. INCLUDES THE COMMERCIAL AND GOVERNMENT ENTITY (CAGE) CODE OF THE ENTITY CONTROLLING THE INSTRUMENT. | |||
| Reply Instructions: Enter the applicable Reply Code from the table below, followed by the 5-position CAGE Code, a dash, and the document identification number. | |||
| (e.g., TESTJA12345-CWX654321*; | |||
| TESTJA1234A-654321$$JB5556A-663654*; | |||
| TESTJAA2345-654321$JB55566-663654*) | |||
| REPLY CODE | REPLY (AC28) |
|---|---|
| A | SPECIFICATION (Includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical," "average," "nominal," etc.) |
| B | STANDARD (Includes industry or association standards, individual manufacturer standards, etc.) |
| C | DRAWING (This is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard, or other document that may be referenced in a basic governing drawing) |
| ALL* | |||
| SPCL | G | SPECIAL TEST FEATURES | |
| Definition: TEST CONDITIONS AND RATINGS, OR ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS THAT ARE DIFFERENT, MORE CRITICAL, OR MORE SPECIFIC THAN THOSE SPECIFIED IN A GOVERNING TEST DATA DOCUMENT. | |||
| Reply Instructions: Enter the reply in clear text. (e.g., SPCLGSELECTED AND TESTED FOR NAVIGATIONAL SYSTEMS*) | |||
|
|
|||
| ALL * | |||
| AARG | D | RELIABILITY INDICATOR | |
| Definition: AN INDICATION THAT THE LEVEL OF PROBABILITY THAT AN ITEM WILL OPERATE WITHOUT FAILURE, AT A SPECIFIED RATED CAPABILITY, AT A SPECIFIED TEMPERATURE, AND FOR A SPECIFIED PERIOD OF TIME, HAS BEEN ESTABLISHED BY TESTING RANDOM SAMPLES OF PRODUCTION LOT. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., AARGDE*) | |||
| REPLY CODE | REPLY (AA61) |
|---|---|
| E | ESTABLISHED |
| N | NOT ESTABLISHED |
| ALL* | |||
| ZZZK | J | SPECIFICATION/STANDARD DATA | |
| Definition: THE DOCUMENT DESIGNATOR OF THE SPECIFICATION OR STANDARD WHICH ESTABLISHED THE ITEM OF SUPPLY. | |||
| Reply Instructions: Enter the applicable Reply Code from the table below, followed by the Commercial and Government Entity (CAGE) Code of the entity controlling the document, a dash, and the document designator. The agency that controls the limited coordination document must be preceded and followed by a slash following the designator. The word canceled or superseded must be preceded and followed by a slash for the designator. Professional and industrial association specifications/standards are differentiated from a manufacturer's specification in that the data has been coordinated and published by the professional and industrial association. Include amendments and revisions where applicable. | |||
| (e.g., ZZZKJT81337-30642B*; | |||
| ZZZKJS81349-MIL-D-180 REV1/CANCELED/*; | |||
| ZZZKJP80205-NAS1103*; | |||
| ZZZKJS81349-MIL-C-1140C/CE/*; | |||
| ZZZKJT81337-30642B$$JP80205-NAS1103*) | |||
| REPLY CODE | REPLY (AN62) |
|---|---|
| S | GOVERNMENT SPECIFICATION |
| T | GOVERNMENT STANDARD |
| D | MANUFACTURERS SOURCE CONTROL |
| R | MANUFACTURERS SPECIFICATION |
| N | MANUFACTURERS SPECIFICATION CONTROL |
| M | MANUFACTURERS STANDARD |
| B | NATIONAL STANDARD/SPECIFICATION |
| A | PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION |
| P | PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD |
| NOTE FOR MRC ZZZT: IF THE SPECIFICIATION/STANDARD CITED IN REPLY TO MRC ZZZK IS NONDEFINITIVE, REPLY TO MRC ZZZT. THIS REPLY IS THE DATA WHICH IS NOT RECORDED IN SEGMENT C. | |||
| ALL * (See Note Above) | |||
| ZZZT | J | NONDEFINITIVE SPEC/STD DATA | |
| Definition: THE NUMBER, LETTER, OR SYMBOL THAT INDICATES THE TYPE, STYLE, GRADE, CLASS, AND THE LIKE, OF AN ITEM IN A NONIDENTIFYING SPECIFICATION OR STANDARD. | |||
| Reply Instructions: Enter the applicable REPLY CODE from Appendix A, Table 8 , followed by the appropriate number, letter, or symbol. (e.g., ZZZTJTY1*; ZZZTJTY1$$JSTA*; ZZZTJTY1$JSTA*) | |||
|
|
|||
| ALL* | |||
| ZZZW | G | DEPARTURE FROM CITED DOCUMENT | |
| Definition: THE TECHNICAL DIFFERENTIATING CHARACTERISTIC(S) OF AN ITEM OF SUPPLY WHICH DEPART(S) FROM THE TEXT OF A SPECIFICATION OR A STANDARD IN THAT IT REPRESENTS A SELECTION OF CHARACTERISTICS STATED IN THE SPECIFICATION OR STANDARD AS BEING OPTIONAL, OR A VARIATION FROM ONE OR MORE OF THE STATED CHARACTERISTICS, OR AN ADDITIONAL CHARACTERISTIC NOT STATED IN THE SPECIFICATION OR STANDARD. | |||
| Reply Instructions: Enter the reply in clear text. (e.g., ZZZWGAS MODIFIED BY MATERIAL*) | |||
|
|
|||
| ALL* | |||
| ZZZX | G | DEPARTURE FROM CITED DESIGNATOR | |
| Definition: THE VARIATION WHEN THE ITEM IS IN CONFORMITY WITH A TYPE DESIGNATOR COVERED BY A SPECIFICATION OR STANDARD, EXCEPT IN REGARD TO ONE OR MORE TECHNICAL DIFFERENTIATING CHARACTERISTICS. | |||
| Reply Instructions: Enter the reply in clear text. (e.g., ZZZXGAS MODIFIED BY MATERIAL*) | |||
|
|
|||
| ALL* | |||
| ZZZY | G | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | |
| Definition: A FEATURE OF THE ITEM OF SUPPLY WHICH MUST BE SPECIFICALLY RECORDED WHEN THE REFERENCE NUMBER COVERS A RANGE OF ITEMS. | |||
| Reply Instructions: Enter the reply in clear text. (e.g., ZZZYGCOLOR CODED LEADS*; ZZZYGAS DIFFERENTIATED BY MATERIAL*) | |||
|
|
|||
| ALL* | |||
| CRTL | A | CRITICALITY CODE JUSTIFICATION | |
| Definition: THE MASTER REQUIREMENT CODES OF THOSE REQUIREMENTS WHICH ARE TECHNICALLY CRITICAL BY REASON OF TOLERANCE, FIT, PERFORMANCE, OR OTHER CHARACTERISTICS WHICH AFFECT IDENTIFICATION OF THE ITEM. | |||
| Reply Instructions: Enter the Master Requirement Code for the requirement, the reply to which renders the item as being critical. (e.g., CRTLAMATL*; CRTLAMATL$$ASURF*) | |||
| Reply to this requirement only if the header record for the item identification for the item being identified has been coded as critical. | |||
|
|
|||
| NOTE FOR MRC PRPY: IF DOCUMENT AVAILABILITY CODE B, D, F, OR H, REPLY TO MRC PRPY. | |||
| ALL* (See Note Above) | |||
| PRPY | A | PROPRIETARY CHARACTERISTICS | |
| Definition: IDENTIFICATION OF THOSE CHARACTERISTICS INCLUDED IN THE DESCRIPTION FOR WHICH A NON-GOVERNMENT ACTIVITY HAS IDENTIFIED ALL OR SELECTED CHARACTERISTICS OF THE ITEM AS BEING PROPRIETARY AND THEREFORE RESTRICTED FROM RELEASE OUTSIDE THE GOVERNMENT WITHOUT PRIOR PERMISSION OF THE ORIGINATOR OF THE DATA. | |||
| Reply Instructions: Enter the MRC codes of the individual characteristics of the description which are marked proprietary on the technical data, using AND coding ($$) for multiple characteristics. If all the MRCs are proprietary, enter the reply PACS. If none of the MRCs is proprietary, enter the reply NPAC. (e.g., PRPYAPACS*; PRPYANPAC*; PRPYAMATL$$ASURF*) | |||
|
|
|||
| ALL* | |||
| ELRN | G | EXTRA LONG REFERENCE NUMBER | |
| Definition: A REFERENCE NUMBER EXCEEDING 32 POSITIONS. | |||
| Reply Instructions: Enter the entire reference number. Do not include the 5-position Commercial and Government Entity (CAGE) Code. (e.g., ELRNGANN112036BIL060557LEN0313605UZ062365*) | |||
| In determining quantity of characters in the reference number, count will be made after modification in accordance with Volume 2, Chapter 9, FLIS Procedures Manual, DoD 4100.39-M. | |||
|
|
|||
| NOTE FOR MRC NHCF: IF THE CRITICALITY CODE IS E, H, OR M, REPLY TO MRC NHCF. | |||
| ALL* (See Note Above) | |||
| NHCF | D | NUCLEAR HARDNESS CRITICAL FEATURE | |
| Definition: AN INDICATION OF THE NUCLEAR HARDNESS CRITICALITY OF THE ITEM. | |||
| Reply Instructions: Enter the Reply Code from the table below. (e.g., NHCFDCY*) | |||
| REPLY CODE | REPLY (AD05) |
|---|---|
| CY | HARDENED |
| ALL* | |||
| ELCD | D | EXTRA LONG CHARACTERISTIC DESCRIPTION | |
| Definition: A DESCRIPTION THAT EXCEEDS 5000 CHARACTERS. | |||
| Reply Instructions: Enter the Reply Code from the table below. (e.g., ELCDDA*) | |||
| REPLY CODE | REPLY (AN58) | ||
|---|---|---|---|
| A | ADDITIONAL DESCRIPTIVE DATA ON MANUAL RECORD | ||
| The excess characters will be mailed to DLIS on DD Form 146 for review and manual control pending machine processing. | |||
|
|
|||
| ALL | |||
| BJBR | J | MAXIMUM POWER DRAIN RATING | |
| Definition: THE MAXIMUM POWER DRAIN FOR WHICH THE ITEM IS RATED. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the numeric value. (e.g., BJBRJBC1.2*) | |||
| REPLY CODE | REPLY (AB49) |
|---|---|
| BC | KILOWATTS |
| BZ | MILLIWATTS |
| AT | WATTS |
| ALL | |||
| ABBH | D | INCLOSURE MATERIAL | |
| Definition: THE ELEMENT, COMPOUND, OR MIXTURE OF WHICH THE INCLOSURE IS FABRICATED, EXCLUDING ANY SURFACE TREATMENT. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., ABBHDALC000*) | |||
| REPLY CODE | REPLY (AD09) |
|---|---|
| ALC000 | ALUMINUM |
| BR0000 | BRASS |
| PC0000 | PLASTIC |
| ST0000 | STEEL |
| STD000 | STEEL, STAINLESS |
| WD0000 | WOOD |
| ALL | |||
| HUES | D | COLOR | |
| Definition: A CHARACTERISTIC OF LIGHT THAT CAN BE SPECIFIED IN TERMS OF LUMINANCE, DOMINANT WAVELENGTH, AND PURITY. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., HUESDBL0000*) | |||
| REPLY CODE | REPLY (AD06) |
|---|---|
| A | ANY ACCEPTABLE |
| BL0000 | BLACK |
| GY0000 | GRAY |
| NA0000 | NATURAL |
| LD0000 | OLIVE DRAB |
| ALL | |||
| ABSW | D | SURFACE LUSTER | |
| Definition: THE APPEARANCE OF THE SURFACE OF AN ITEM AS TO ITS REFLECTING QUALITIES. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., ABSWDB*) | |||
| REPLY CODE | REPLY (AB46) |
|---|---|
| G | HAMMERED |
| B | MATTE (dull) |
| A | MIRROR (glossy) |
| H | SCRATCH GRAIN |
| J | WRINKLE |
| ALL | |||
| MARK | G | SPECIAL MARKINGS | |
| Definition: MARKINGS INCLUDED ON AN ITEM FOR THE PURPOSE OF OFFERING INSTRUCTIONS OR WARNINGS OR TO INDICATE THE PURPOSE, FUNCTION, OR APPLICATION OF THE ITEM. EXCLUDES MANUFACTURERS PART NUMBERS, SYMBOLS, OR THE LIKE. | |||
| Reply Instructions: Enter all special markings in clear text. Separate multiple replies with a semicolon. | |||
| (e.g., MARKGDANGER - HIGH VOLTAGE*; | |||
| MARKGFLAMMABLE; FRAGILE*) | |||
|
|
|||
| ALL | |||
| BBRJ | D | SPECIAL HANDLING FEATURE | |
| Definition: THE UNUSUAL OR UNIQUE CHARACTERISTIC(S) OR QUALITY(IES) OF AN ITEM WHICH NECESSITATES THE ESTABLISHMENT OF A REQUIREMENT FOR SPECIAL HANDLING. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., BBRJDAC*) | |||
| REPLY CODE | REPLY (AM83) |
|---|---|
| AC | EXPLOSIVE |
| AD | FLAMMABLE |
| AE | FRAGILE |
| AK | MAGNETIC |
| AH | RADIOACTIVE |
| NOTE FOR MRC AFJN: REPLY TO THIS MRC ONLY IF REPLY CODE AE IS ENTERED FOR MRC BBRJ. | |||
| ALL (See Note Above) | |||
| AFJN | D | FRAGILITY FACTOR | |
| Definition: THE MEASURE OF SENSITIVITY OF THE ITEM TO BE PACKAGED. A FACTOR USED BY PACKAGING ENGINEERS IN DEVISING PROPER CUSHIONING IN A PACKAGE. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., AFJNDC*) | |||
| REPLY CODE | REPLY (AD40) |
|---|---|
| D | DELICATE |
| B | EXTREMELY FRAGILE |
| E | MODERATELY DELICATE |
| F | MODERATELY RUGGED |
| G | RUGGED |
| C | VERY DELICATE |
| ALL | |||
| BBRG | D | STORAGE TYPE | |
| Definition: INDICATES THE TYPE OF STORAGE SPACE REQUIRED FOR AN ITEM IN ORDER TO PROVIDE THE DEGREE OF PROTECTION NECESSARY TO MAINTAIN SERVICEABILITY STANDARDS. | |||
| Reply Instructions: Enter the applicable REPLY CODE from Appendix A, Table 9 . (e.g., BBRGDAC*) | |||
|
|
|||
| NOTE FOR MRC RADD: REPLY TO THIS MRC IF A REPLY IS ENTERED FOR MRC RADC IN SECTION I. | |||
| ALL (See Note Above) | |||
| RADD | J | RADIONUCLIDES DATA | |
| Definition: THE NAME AND AMOUNT OF THE RADIONUCLIDE. | |||
| Reply Instructions: Enter the applicable Reply Codes from the table below and Appendix A, Table 10 , followed by the numeric value. (e.g., RADDJJFAAAD10.000*) | |||
| Where radioactivity varies from one sample to another, enter the maximum value. | |||
| REPLY CODE | REPLY (AG67) |
|---|---|
| JF | CURIES |
| JH | MICROCURIES |
| JG | MILLICURIES |
| ALL | |||
| AFJQ | J | STORAGE TEMP RANGE | |
| Definition: THE MINIMUM AND MAXIMUM TEMPERATURES AT WHICH AN ITEM CAN BE STORED WITHOUT DETRIMENTAL EFFECT. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the numeric values separated by a slash. Precede negative valves with an M and positive valves with a P. (e.g., AFJQJFM10.0/P110.0*; AFJQJCM22.0/P42.0*) | |||
| REPLY CODE | REPLY (AB36) |
|---|---|
| C | DEG CELSIUS |
| F | DEG FAHRENHEIT |
| ALL | |||
| AGAV | G | END ITEM IDENTIFICATION | |
| Definition: THE NATIONAL STOCK NUMBER OR THE IDENTIFICATION INFORMATION OF THE END EQUIPMENT FOR WHICH THE ITEM IS A PART. | |||
| Reply Instructions: Enter the applicable reply in clear text. | |||
| (e.g., AGAVG3930-00-000-0000*; | |||
| AGAVGFORKLIFT TRUCK, SMITH CORPORATION, MODEL 12, TYPE A*) | |||
|
|
|||
| ALL | |||
| AFJK | J | CUBIC MEASURE | |
| Definition: A MEASUREMENT OF VOLUME TAKEN BY MULTIPLYING THE LENGTH BY THE WIDTH BY THE HEIGHT OF AN ITEM AND RENDERED IN CUBIC UNITS. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the numeric value. (e.g., AFJKJF27.000*; AFJKJC8.1*) | |||
| REPLY CODE | REPLY (AD42) |
|---|---|
| C | CUBIC CENTIMETERS |
| F | CUBIC FEET |
| B | CUBIC INCHES |
| E | CUBIC METERS |
| ALL | |||
| PRMT | D | PRECIOUS MATERIAL | |
| Definition: IDENTIFICATION OF THE PRECIOUS MATERIAL CONTAINED IN THE ITEM. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., PRMTDAGA000*; PRMTDAUA000$$DAGA000*; PRMTDAGA000$DAUA000*) | |||
| REPLY CODE | REPLY (MA01) |
|---|---|
| AUA000 | GOLD |
| IRA000 | IRIDIUM |
| AZA000 | OSMIUM |
| PDA000 | PALLADIUM |
| PTA000 | PLATINUM |
| RHA000 | RHODIUM |
| RTA000 | RUTHENIUM |
| AGA000 | SILVER |
| ALL | |||
| PMWT | J | PRECIOUS MATERIAL AND WEIGHT | |
| Definition: AN INDICATION OF THE PRECIOUS MATERIAL CONTAINED IN THE ITEM, AND THE AMOUNT PER A MEASUREMENT SCALE. | |||
| Reply Instructions: Enter the applicable Reply Codes from Tables 1 and 2 below, followed by the numeric value. Enter multiple replies in Table 1 sequence. (e.g., PMWTJPTA000R0.780*; PMWTJAUA000F0.500$$JAGA000R0.780*; PMWTJAUA000F0.500$JAGA000R0.780*) | |||
| Table 1 | |
|---|---|
| REPLY CODE | REPLY (MA01) |
| AUA000 | GOLD |
| IRA000 | IRIDIUM |
| AZA000 | OSMIUM |
| PDA000 | PALLADIUM |
| PTA000 | PLATINUM |
| RHA000 | RHODIUM |
| RTA000 | RUTHENIUM |
| AGA000 | SILVER |
| Table 2 | |
|---|---|
| REPLY CODE | REPLY (AG14) |
| E | GRAINS, TROY |
| R | GRAMS |
| F | OUNCES, TROY |
| ALL | |||
| PMLC | J | PRECIOUS MATERIAL AND LOCATION | |
| Definition: AN INDICATION OF THE PRECIOUS MATERIAL AND ITS LOCATION IN THE ITEM. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below, followed by the location in clear text. (e.g., PMLCJAUA000TERMINALS*; PMLCJAUA000TERMINALS$$JAGA000INTERNAL SURFACES*; PMLCJAGA000TERMINALS$JAUA000INTERNAL SURFACES*) | |||
| REPLY CODE | REPLY (MA01) |
|---|---|
| AUA000 | GOLD |
| IRA000 | IRIDIUM |
| AZA000 | OSMIUM |
| PDA000 | PALLADIUM |
| PTA000 | PLATINUM |
| RHA000 | RHODIUM |
| RTA000 | RUTHENIUM |
| AGA000 | SILVER |
| ALL | |||
| SUPP | G | SUPPLEMENTARY FEATURES | |
| Definition: CHARACTERISTICS OR QUALITIES OF AN ITEM, NOT COVERED IN ANY OTHER REQUIREMENT, WHICH ARE CONSIDERED ESSENTIAL INFORMATION FOR ONE OR MORE FUNCTIONS EXCLUDING NSN ASSIGNMENT. | |||
| Reply Instructions: Enter the reply in clear text. (e.g., SUPPGMAY INCL HOLE IN UPPER SUPPORT FOR MTG DURING SHIPMENT*) | |||
|
|
|||
| ALL | |||
| FCLS | A | FUNCTIONAL CLASSIFICATION | |
| Definition: THE ALPHA-NUMERIC DESIGNATION THAT IDENTIFIES THE CLASSIFICATION OF THE ITEM ACCORDING TO THE CATEGORY OF FUNCTIONS PERFORMED. | |||
| Reply Instructions: Enter the reply from the applicable document. | |||
| (e.g., FCLSAHH-1.5*) | |||
|
|
|||
| ALL | |||
| FTLD | G | FUNCTIONAL DESCRIPTION | |
| Definition: DESCRIBES THE CAPABILITIES, INTENDED USE, AND/OR PURPOSE FOR WHICH THE ITEM IS PROVIDED. | |||
| Reply Instructions: Enter description of function as concisely as possible. (e.g., FTLDGUSED TO INSTALL/REMOVE ENGINE NACELLE*) | |||
|
|
|||
| ALL | |||
| TMDN | A | TYPE/MODEL DESIGNATION | |
| Definition: THE ALPHA-NUMERIC-ALPHA DESIGNATION USED TO IDENTIFY THE TYPE AND/OR MODEL OF THE BASIC ITEM. | |||
| Reply Instructions: Enter the appropriate designation data. | |||
| (e.g., TMDNAMSV-615/M*) | |||
|
|
|||
| ALL | |||
| RTSE | G | RELATIONSHIP TO SIMILAR EQUIPMENT | |
| Definition: INDICATES THE RELATIONSHIP, SUCH AS CONSTRUCTION, CAPABILITIES, AND THE LIKE, OF THE ITEM TO A SIMILAR ITEM. | |||
| Reply Instructions: Enter concise statement for similar item including name and identifying data. | |||
| (e.g., RTSEGSIMILAR TO LOCKHEED OVERWING ENGINE HOIST P/N 61521-58*) | |||
|
|
|||
| ALL | |||
| RDAL | G | REFERENCE DATA AND LITERATURE | |
| Definition: LITERATURE AND REFERENCES AVAILABLE FOR INFORMATION PERTAINING TO THE ITEM. | |||
| Reply Instructions: Enter data appropriate and in a concise manner to identify informational references covering the item. | |||
| (e.g., RDALGNAAVAIROIA/VFK58 A-2.2.9*) | |||
|
|
|||
| ALL | |||
| NTRD | A | ENTRY DATE | |
| Definition: INDICATES THE DATE THE ITEM WAS ENTERED INTO MIL-HDBK-300. | |||
| Reply Instructions: Enter the date structured in three hyphenated 2 position segments to indicate the last 2 digits of the calendar year, month, and day. | |||
| (e.g., NTRDA80-05-28*) | |||
|
|
|||
| ALL | |||
| ZZZP | J | PURCHASE DESCRIPTION IDENTIFICATION | |
| Definition: THE CONTROLLING ACTIVITY AND IDENTIFICATION OF A DOCUMENT USED IN LIEU OF A SPECIFICATION IN THE PROCUREMENT OF AN ITEM OF SUPPLY. | |||
| Reply Instructions: Enter the 5-position Commercial and Government Entity (CAGE) Code, followed by a dash and the identifying number of the document. | |||
| (e.g., ZZZPJ81337-30624A*) | |||
|
|
|||
| ALL | |||
| ZZZV | G | FSC APPLICATION DATA | |
| Definition: THE JUSTIFICATION FOR THE ASSIGNMENT OF A FEDERAL SUPPLY CLASS (FSC) TO AN ITEM BASED ON THE CLASSIFICATION OF THE NEXT HIGHER CLASSIFIABLE ASSEMBLY. | |||
| Reply Instructions: Enter the name of the next higher classifiable assembly in clear text. (e.g., ZZZVGCOUNTER MEASURES SETS*) | |||
|
|
|||
| ALL | |||
| HZRD | D | HAZARDOUS SUBSTANCES | |
| Definition: THE SUBSTANCES AND/OR MATERIALS CONTAINED IN THE ITEM THAT HAVE BEEN IDENTIFIED AS HAZARDOUS OR ENVIRONMENTALLY DAMAGING BY THE ENVIRONMENTAL PROTECTION AGENCY OR OTHER AUTHORIZED GOVERNMENT AGENCY. | |||
| Reply Instructions: Enter the applicable REPLY CODE from the table below. (e.g., HZRDDHAZ035*) | |||
| REPLY CODE | REPLY (HZ00) |
|---|---|
| HAZ035 | RADIOACTIVE |
| ALL * | |||
| CXCY | G | PART NAME ASSIGNED BY CONTROLLING AGENCY | |
| Definition: THE NAME ASSIGNED TO THE ITEM BY THE GOVERNMENT AGENCY OR COMMERCIAL ORGANIZATION CONTROLLING THE DESIGN OF THE ITEM. | |||
| Reply Instructions: Enter the reply in clear text. (e.g., CXCYGLINE PROCESSOR CONTROL BOARD*) | |||